Problems Resolved by Version 2.04
24338,
36286
Problem with reference address and length parameters for genius mixed devices
Details: When user configures length as zero for genius mixed devices then reference address
associated and length parameter will become invisible. Same problem exists after import from
LM90 and also after upload. This is an usability issue and user has to replace the module
reconfigure this reference address.
Resolution: This is fixed in VersaPro 2.04. Reference address and length parameters will be
visible even when length field is zero.
27346
VersaPro crashes while changing redundancy mode to none for BEM731
Details: Configure IC697BEM731 module and set redundancy mode to a mode other than
none. Close and open project, Set the mode back to none and VersaPro crashes at this point.
Resolution: This has been fixed in VersaPro 2.04.
27349
VersaPro does not update C-Blocks if file size does not change
Details: Download a C-block into PLC and Update this C-block with totally different binary
but of same size. VersaPro 2.03 doesn’t update this new binary as they are of same size and
shows logic equal with PLC. Deleting the C-
lock from the folder and reinserting it is the only
way to get VersaPro to update the c-block
Resolution: This has been corrected in VersaPro 2.04. C-blocks get correctly updated even if
they are of same size.
30918
VersaPro crashes when open old Nano/micro version file
Details: Create a VersaMax Nano/micro project in VersaPro 2.0 and open the same in 2.03.
VersaPro 2.03 gets crashed when we double click on any of the parameters in HWC editor.
Resolution: This issue is fixed in VersaPro 2.04.
31303
Re-Install problem when there is any file with name VersaPro is open
Details: VersaPro doesn’t re-install if you have any file with name VersaPro (Eg:VersaPro.txt)
is open. It gives a message “ Instance of VersaPro is running and cannot be installed”. It
considers as if VersaPro is running and aborts installation process.
Resolution: This has been is fixed in VersaPro 2.04. Now it gives this message only when
VersaPro application is open.
31847
Series 90 Micro item is not being shown in options for Nano/Micro build
Details: VersaPro doesn’t show Series 90 Micro item in tools/options => PLC select Listbox
for Nano/Micro build.
Resolution: This is fixed in VersaPro 2.04. Series 90 Micro item is added in the listbox for
nano/micro build.
32173
Port Configuration problem on PCM711 using VersaPro
Details: Configure PCM 711 with Port1 as CCM Master and Port2 as Programmer.
Downloading configuration to PLC will put PLC in fault mode with fault code “Unsupported
feature in configuration.
Resolution: This issue has been fixed in VersaPro 2.04. PLC will not go into fault mode.
32355
Power consumption calculation method is wrong for VersaMax racksystem
Resolution: Formula for this calculation was wrong and has been corrected in VersaPro 2.04.
32770,
34236,
36016
Incorrect power consumption values for few 9030 i/o modules
Resolution: Values are corrected in VersaPro 2.04 for modules – IC693MDL640,
IC693MDL641, IC693MDL645, IC693MDL655, IC693ALG390
33359
Coil on CV of timer/counter in column 9 halts PLC
Details: Put a timer or counter in column 9, and then add a coil on CV in column 10. Run this
on a 90-70 PLC and it will halt the CPU.
Resolution: This issue has been fixed in VersaPro 2.04.